MIL-G-8968 (ASG)
National Bureau of Standards
Screw-Threads Standards for Federal Services
Handbook H2B
(Application for copies of the above publication should be addressed to
the Superintendent of Documents, Government Printing office, Washington, D. C. 20402.)
United States of America Standards Institute
National Electrical Code
C1-1965
General Purpose Sound Level Meters, Specification for
S1.4-1961
Referred Frequencies and Band Numbers for Acoustical
S1.6-1967
Measurements
Octane Bend Filter Set for Analysis of Noise and
Z24.10
Other Sounds
(Application for copies should be addressed to the United States of America
Standards Institute, 10 East 40th Street) New York, New York 10016.)
Uniform Classification Committee
Uniform Freight Classification Rules
(Application for copies of the above publication should be addressed to the
Uniform Classification Committee, 202 Chicago Union Station, Chicago, Illinois 60606.)
3. REQUIREMENTS
3.1 Preproduction. - This specification makes provisions for preproduction
inspection (see 4.4).
3.2 Components. - The plant shall consist of the following major components:
Trailer van assembly
Air source assembly
.
Air liquefaction and separation assembly
3.2.1 General description. - The major components listed in 3.2 shall constitute
a liquid oxygen-liquid nitrogen generating plant which shall be a compact, completely
self-contained trailer mounted unit requiring only a supply of aviation fuel and
ambient air, plus the necessary absorbents and lubricants to liquefy and separate air
into oxygen and nitrogen, The plant shall be mounted on a two-axle, four-wheel trail-
er, and shall be air transportable. All electrical switch gear, wiring, and lighting
equipment, piping, ducting, controls, instruments, and accessory components needed
for operation and maintenance of the generating plant shall be provided.